SCP CAT6-PREM-LS-BK is a U/UTP category 6 network cable made of solid 23+ AWG copper, with a bandwidth of 550MHz, PoE support up to 90W, and an LSZH coating in class Dca, in a Reelex 305m carton

CAT6-PREM-LS-BK

installation U/UTP category 6 network cable, 23AWG, Cu LSZH Dca, black, 305m

Catalogue index: SCP000193

  • Delivery time: 14 days
  • Delivery: from €0.00 (InPost)
€439.86 net / 305m €541.03 gross incl. 23% VAT / 305m

Description

SCP CAT6-PREM-LS-BK - U/UTP category 6 network cable, 4x2x23+ AWG, copper wire (Cu), flame-retardant separator, black LSZH Dca coating, 305m (Reelex carton)

SCP CAT6-PREM-LS-BK is an unshielded U/UTP category 6 network cable from the Cat6 Premium Pro series, designed for structured cabling inside buildings. In tests, it achieves a bandwidth of 550MHz, more than double the required 250MHz standard, and provides stable transmission in Gigabit Ethernet networks, and on shorter runs also 10Gb/s. The solid 23+ AWG copper conductors have lower resistance, making the cable well-suited for high-power PoE up to 90W and HDBaseT transmission. The separator separates pairs and reduces crosstalk. The flame-retardant LSZH coating in fire reaction class Dca-s2,d2,a1 emits low smoke and does not release halogen compounds during a fire, allowing the cable to be used in public buildings, offices, hotels, schools, and hospitals. The cable undergoes independent ETL verification. It is delivered in a Reelex II carton, which allows for unwinding without twisting and tangling, and the coating is printed with decreasing footage and zone legends, facilitating installation and cable marking.

Functionality

  • Data transmission 1Gb/s (1000BASE-T) in a run up to 100m and 10Gb/s (10GBASE-T) on shorter runs, up to 55m
  • Bandwidth 550MHz confirmed in tests, with a large margin above category 6 requirements
  • PoE power IEEE 802.3bt Type 3/4 up to 60W and 90W for cameras, Wi-Fi access points, LED lighting, and terminals
  • HDBaseT support (HDBaseT Recognized) in AV over IP systems, extenders, and digital signage
  • Solid 23+ AWG copper conductors with lower resistance and less heating during PoE power
  • Separator reducing crosstalk between pairs
  • Flame-retardant LSZH coating with low smoke emission and no halogens, in CPR class Dca-s2,d2,a1
  • Reelex II carton for unwinding the cable without twisting and tangling
  • Printed decreasing footage and zone/device legends (ZONE/DEVICE) facilitating cable marking
  • Nylon string for cutting the coating

Features

  • Category: 6, class E
  • Type: U/UTP, unshielded
  • Bandwidth: 550MHz (tested), 250MHz according to TIA
  • Number of pairs: 4
  • Conductor: solid bare copper (Cu), 23+ AWG
  • Insulation thickness: HDPE, 0.24mm
  • Conductor diameter in insulation: 1.05mm
  • Separator: PE, 4.2 x 4.2 x 0.5mm
  • Coating: flame-retardant LSZH (FR-LSZH), black, thickness 0.55mm
  • Outer diameter: 6.3mm
  • Characteristic impedance: 100Ω ±15Ω
  • Conductor resistance: 8.0Ω/100m (20°C)
  • Insulation resistance: ≥5000MΩ·km
  • Mutual capacitance: ≤56nF/km
  • Propagation delay (NVP): 66%
  • Delay skew: ≤45ns/100m
  • Rated voltage: 300V
  • PoE: IEEE 802.3bt Type 3/4, 60W/90W
  • Minimum bending radius: 50.4mm (installation), 25.2mm (operation)
  • Maximum pulling force: 85N
  • Operating temperature: -20-75°C
  • Installation temperature: 0-40°C
  • Storage temperature: 0-40°C
  • Fire reaction class: Dca-s2,d2,a1 (EN 50575)
  • Standards: ANSI/TIA 568.2-D, ISO/IEC 11801 class E, EN 50173-1, EN 50288-5-1, EN 50288-6-1, IEC 61156-5
  • Certifications and compliance: ETL Verified, CE, RoHS, REACH
  • Packaging: 305m, Reelex II carton
  • Packaging weight: 14.5kg
  • Packaging dimensions: 400 x 290 x 400mm

SCP CAT6-PREM-LS-BK is a U/UTP category 6 cable that combines a bandwidth of 550MHz, solid 23+ AWG copper conductors, and PoE support up to 90W with a flame-retardant LSZH coating in class Dca. ETL verification, printed footage with zone legends, and Reelex II carton make the cable well-suited for professional structured cabling in IT networks, AV systems, and monitoring in buildings with enhanced fire safety requirements.